1)Elasticity reconstruction from experimental MR displacement data: initial experience with an overlapping subzone finite element inversion process,” E.E.W. Van Houten, J.B. Weaver, M.I. Miga, F.E. Kennedy, K.D. Paulsen, Medical Physics, 27(1):101–107, 2000.( VanHouten_MPH_2000.pdf)
2) Three-dimensional steady state acquisition and reconstruction in MR elastography,J.B. Weaver, E. Van Houten, M.I. Miga, F.E. Kennedy, K.D. Paulsen, Radiology, Suppl. S 217:30, 2000.
3) A three dimensional subzone based reconstruction algorithm for MR elastography,E.E.W. Van Houten, M.I. Miga, J.B. Weaver, and K.D. Paulsen, Magnetic Resonance in Medicine, 45(5):827-837, 2001.(VanHouten_MRM_2001)
4) MR elastography using 3D gradient echo measurements of steady state motion,J.B. Weaver, E.E.W. Van Houten, M.I. Miga, F.E. Kennedy and K.D. Paulsen, Medical Physics, 28(8):1620-1628, 2001. (Weaver_MPH_2001.pdf)
5) Thresholds for detecting and characterizing focal lesions using steady-state MR elastography,M M. Doyley,J.B. Weaver, E E. W. Van Houten and F E. Kennedy  K D. Paulsen, Medical Physics, 30(4): 495-504,2003.(Doyley_MPH_2003.pdf)
6) Initial in vivo experience with steady-state subzone-based MR elastography of the human breast,E.E.W. Van Houten, M.M. Doyley, F.E. Kennedy, J.B. Weaver and K.D. Paulsen, Journal of Magnetic Resonance Imaging, 17(1):72-85, 2003. (VanHouten_JMRM_2003.pdf)
7) Breast deformation modelling for image reconstruction in near infrared optical tomography,H. Dehghani, M.M. Doyley, B.W. Pogue, S.D. Jiang, J. Geng and K.D. Paulsen, Physics in Medicine and Biology, 49(7):1131-1145, 2004. (Dehghani_PMB_2004.pdf)
8) Shear modulus estimation using parallelized partial volumetric reconstruction, M.M. Doyley, E.E.W. Van Houten, J.B. Weaver, S. Poplack, L. Duncan, F. Kennedy and K.D. Paulsen, IEEE Transactions on Medical Imaging, 23(11):1404-1416, 2004. (Doyley_IEEE_TMI_2004.pdf)
9) A three-parameter mechanical property reconstruction method for MR-based elastic property imaging, E.E.W. Van Houten, M.M. Doyley, F.E. Kennedy, K.D. Paulsen and J.B. Weaver, IEEE Transactions on Medical Imaging, 24(3):311-324, 2005. (VanHouten_IEEE_TMI_2005.pdf)
10) Imaging the shear modulus of the heel fat pads,J.B. Weaver, M.M. Doyley, Y. Cheung, F.E. Kennedy, E.L. Madsen, E.E.W. Van Houten, K.D. Paulsen, Clinical Biomech, (Bristol, Avon), 20(3):312-319, 2005. (8. Weaver_Clin_Biomech_2005.pdf)
11) Magnetic resonance elastography of the plantar fat pads: Preliminary study in diabetic patients and asymptomatic volunteers, Cheung YY. Doyley MM, Miller TB, Kennedy F, Lynch F Jr, Wrobel JS, Paulsen K, Weaver J. J Comput Assist Tomogr. 30(2):321-6,2006.
12). Performance analysis of steady-state harmonic elastography,MM Doyley, Q Feng, JB Weaver, KD Paulsen, Physics in Medicine and Biology 52, 2007 (Doyley_PMB_2007-proof.pdf)